Main scientific studies presented at the European Congress of Rheumatology 2020

 

1. Influence of the variation of the operator, patient position and device on the measurement performance of R.E.M.S

Caffarelli, G. Adami, G. Arioli, G. Bianchi, M.L. Brandi, S. Casciaro. L. Cianferotti, D. Ciardo, F. Conversano, D. Gatti, G. Girasole, M. Manfredini, M. Muratore, P. Pisani, E. Quarta, L. Quarta, S. Gonnelli

Highlight:

This study evaluates intra-operator, inter-operator and inter-device repeatability for estimates obtained using REMS technology on more than 200 women; a high precision has been reported for both sites, lumbar spine and proximal femur, as well as a high repeatability.

Department of Medicine, Surgery and Neurosciences, University of Siena, Siena, Italy

Rheumatology Unit, Department of Medicine, University of Verona, Verona, Italy

Department of Neurosciences and Rehabilitation, “Carlo Poma” Hospital, ASST-Mantova, Mantova, Italy

SC Rheumatology, ASL 3 Genovese, Genoa, Italy

Department of Surgery and Translational Medicine, University of Florence, Metabolic Bone Diseases Unit, University Hospital of Florence, Florence, Italy

National Research Council, Institute of Clinical Physiology, Lecce, Italy

O.U. of Rheumatology, “Galateo” Hospital, San Cesarion di Lecce ASL-LE, Lecce, Italy

 

Download pdf.

 

 

2. REMS Technology applied to rheumatic diseases

M.D. Tomai Pitinca, C. Caffarelli, S. Gonnelli

Highlight:

The results of this study acknowledge that REMS technology can be considered an added value in examining patients with rheumatologic diseases causing alterations in the spine, which typically reduce the diagnostic sensitivity of DXA.

National Research Council, Institute of Clinical Physiology, Lecce, Italy

Department of Medicine, Surgery and Neurosciences, University of Siena, Siena, Italy

 

Download pdf.

 

3. Short-term monitoring of denosumab effect in breast cancer patients receiving Aromatase Inhibitors using REMS technology on lumbar spine

Quarta, D. Ciardo, M. Ciccarese, F. Conversano, M. Di Paola, R. Forcignanò, F.A. Lombardi, M. Muratore, P. Pisani, L. Quarta, S. Casciaro

Highlight:

The results of this study prove the clinical effectiveness of REMS technology for short-term monitoring of patients under therapeutic therapy, a clinical need which is currently unmet by other methods including the gold standard DXA.

O.U. of Rheumatology, “Galateo” Hospital, San Cesario di Lecce, ASL-LE, Lecce, Italy

National Research Council, Institute of Clinical Physiology, Lecce, Italy

O.U. of Oncology, “Vito Fazzi” Hospital, ASL-LE, Lecce, Italy

 

Download pdf.

Fragility Score Publication

Fragility Score Publication

“Fragility Score: a REMS‑based indicator for the prediction of incident fragility fractures at 5 years” Paola Pisani1 Francesco Conversano1 Maurizio Muratore2 Giovanni Adami3 Maria Luisa Brandi4 Carla Cafarelli5 Ernesto Casciaro1 Marco Di Paola1 Roberto...

read more
REMS in Nefrology

REMS in Nefrology

PAPER OF THE MONTH BY ESCEO Prestigious recognition from ESCEO for REMS applied to dialysis patients Finally diagnosis and monitoring are also available to dialysis patients: REMS technology offers new and great opportunities also for this category of fragile...

read more
REMS in Springer book

REMS in Springer book

Pulse-Echo Measurements of Bone Tissues. Techniques and Clinical Results at the Spine and Femur The Advances in Experimental Medicine and Biology book series (AEMB, volume 1364) now provides a review of the available pulse-echo approaches for the quantitative...

read more

    Contact Us

    More info or book a demo.



    Position*

    *Required fields




    This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

    Copyright © 2021 - Echolight S.p.a Tutti i diritti riservati