Main scientific studies presented at the European Congress of Rheumatology 2020
1. Influence of the variation of the operator, patient position and device on the measurement performance of R.E.M.S
Caffarelli, G. Adami, G. Arioli, G. Bianchi, M.L. Brandi, S. Casciaro. L. Cianferotti, D. Ciardo, F. Conversano, D. Gatti, G. Girasole, M. Manfredini, M. Muratore, P. Pisani, E. Quarta, L. Quarta, S. Gonnelli
Highlight:
This study evaluates intra-operator, inter-operator and inter-device repeatability for estimates obtained using REMS technology on more than 200 women; a high precision has been reported for both sites, lumbar spine and proximal femur, as well as a high repeatability.
Department of Medicine, Surgery and Neurosciences, University of Siena, Siena, Italy
Rheumatology Unit, Department of Medicine, University of Verona, Verona, Italy
Department of Neurosciences and Rehabilitation, “Carlo Poma” Hospital, ASST-Mantova, Mantova, Italy
SC Rheumatology, ASL 3 Genovese, Genoa, Italy
Department of Surgery and Translational Medicine, University of Florence, Metabolic Bone Diseases Unit, University Hospital of Florence, Florence, Italy
National Research Council, Institute of Clinical Physiology, Lecce, Italy
O.U. of Rheumatology, “Galateo” Hospital, San Cesarion di Lecce ASL-LE, Lecce, Italy
2. REMS Technology applied to rheumatic diseases
M.D. Tomai Pitinca, C. Caffarelli, S. Gonnelli
Highlight:
The results of this study acknowledge that REMS technology can be considered an added value in examining patients with rheumatologic diseases causing alterations in the spine, which typically reduce the diagnostic sensitivity of DXA.
National Research Council, Institute of Clinical Physiology, Lecce, Italy
Department of Medicine, Surgery and Neurosciences, University of Siena, Siena, Italy
3. Short-term monitoring of denosumab effect in breast cancer patients receiving Aromatase Inhibitors using REMS technology on lumbar spine
Quarta, D. Ciardo, M. Ciccarese, F. Conversano, M. Di Paola, R. Forcignanò, F.A. Lombardi, M. Muratore, P. Pisani, L. Quarta, S. Casciaro
Highlight:
The results of this study prove the clinical effectiveness of REMS technology for short-term monitoring of patients under therapeutic therapy, a clinical need which is currently unmet by other methods including the gold standard DXA.
O.U. of Rheumatology, “Galateo” Hospital, San Cesario di Lecce, ASL-LE, Lecce, Italy
National Research Council, Institute of Clinical Physiology, Lecce, Italy
O.U. of Oncology, “Vito Fazzi” Hospital, ASL-LE, Lecce, Italy
REMS: Short-Term Precision and Repeatability
“Short-Term Precision and Repeatability of Radiofrequency Echographic Multi Spectrometry (REMS) on Lumbar Spine and Proximal Femur: An In Vivo Study" Carmelo Messina, Salvatore Gitto, Roberta Colombo, Stefano Fusco, Giada Guagliardo, Mattia Piazza, Jacopo Carlo Poli,...
Fragility Score Publication
“Fragility Score: a REMS‑based indicator for the prediction of incident fragility fractures at 5 years” Paola Pisani1 Francesco Conversano1 Maurizio Muratore2 Giovanni Adami3 Maria Luisa Brandi4 Carla Cafarelli5 Ernesto Casciaro1 Marco Di Paola1 Roberto...